我的(de)位置(zhi):首(shou)頁(ye) > 產(chan)品中心 > > 高(gao)壓(ya)短路接地(di)線(xian) > XJ-10KV(線(xian)路(lu))型攜帶型短路接地(di)線(xian)

產(chan)品(pin)型號:
更(geng)新時(shi)間(jian):2018-04-03簡(jian)要(yao)描述:XJ-10KV(線(xian)路)型攜帶型短路接地(di)線(xian)而(er)變電(dian)線路(lu)型接地(di)線(xian)和(he)戶外線(xian)路(lu)型接地(di)線(xian)的(de)接電(dian)夾與(yu)帶電(dian)體的(de)連接部(bu)分壹般(ban)是(shi)銅線(xian)或鋼(gang)芯鋁絞線,所以變電(dian)線路(lu)型接地(di)線(xian)和(he)戶外線(xian)路(lu)型的接地(di)夾(jia)壹(yi)般(ban)采用雙(shuang)簧(huang)卡口式、單簧(huang)卡口式、或猴(hou)頭(tou)壓(ya)緊(jin)式,即(ji):JDX-WS 型雙簧(huang)卡口式接地(di)線(xian)、JDX-WD型單簧(huang)卡口式接地(di)線(xian)和(he)JDX-WL型猴頭(tou)壓(ya)緊(jin)式接地(di)線(xian)。
接地(di)線(xian)使(shi)用(yong)範圍: 10KV配電(dian)室
接地(di)棒(bang)接電(dian)夾型式:XJ-10KV(線路(lu))型攜帶型短路接地(di)線(xian)
接地(di)棒(bang)接電(dian)夾規格:接電(dian)夾開口(kou)口距35mm
接地(di)棒(bang)操(cao)作(zuo)桿規格:0.5m*3根,外徑(jing)Ф30mm,操(cao)作(zuo)桿長(chang)度(du)和(he)外徑(jing)可(ke)根(gen)據用(yong)戶需求(qiu)定(ding)制(zhi)。
接地(di)軟(ruan)銅線(xian)規格: 線徑(jing):25mm,3*1m+5m合相(xiang)式。長度(du)和(he)線(xian)徑(jing)可(ke)根(gen)據用(yong)戶需求(qiu)定(ding)制(zhi)。
適用電(dian)壓(ya)等(deng)級(ji): 10KV
接地(di)線(xian)的(de)分類(lei):不(bu)同(tong)電(dian)壓(ya)等(deng)級(ji)、不(bu)同(tong)使(shi)用(yong)環(huan)境下(xia)的(de)接地(di)線(xian)的(de)具(ju)體配(pei)置(zhi)是(shi)不(bu)同(tong)的(de), 相(xiang)同電(dian)壓(ya)等(deng)級(ji)不(bu)同(tong)使(shi)用(yong)環(huan)境下(xia)的(de)接地(di)線(xian)的(de)具(ju)體配(pei)置(zhi)也是(shi)不(bu)同(tong)的(de)(接地(di)棒(bang)的(de)長(chang)度(du),接電(dian)夾的(de)樣(yang)式,接地(di)軟(ruan)銅線(xian)的(de)粗(cu)細,長度(du),接地(di)方(fang)式等)。所以,用(yong)戶在選(xuan)購(gou)接地(di)線(xian)時(shi)壹(yi)定(ding)要(yao)搞(gao)清(qing)楚(chu)具(ju)體的(de)使用(yong)環境和準確的(de)電(dian)壓(ya)等(deng)級(ji),以便(bian)正確選(xuan)型。
壹、XJ-10KV(線(xian)路(lu))型攜帶型短路接地(di)線(xian)結構特點(dian):
1、線卡等主要(yao)零(ling)件采用鋁(lv)合金壓(ya)力(li)鑄造(zao),線卡經(jing)久耐(nai)用。
2、操(cao)作(zuo)簡便(bian),特別是(shi)彈簧(huang)壓(ya)緊(jin)式,只需往導線(xian)上(shang)壹掛(gua)、壹拉(la)即(ji)可(ke)。
3、配(pei)套合理(li),功(gong)能可(ke)靠(kao)。根據電(dian)壓(ya)等(deng)級(ji),合理(li)選(xuan)用“接地(di)線(xian)”,線(xian)卡結構簡(jian)單(dan),與(yu)導線(xian)接觸面大(da)。
4、線卡實用範(fan)圍大(da),適應不(bu)同(tong)導線(xian)截(jie)面的需要(yao)。
二(er)、實用範(fan)圍:
1、環(huan)境溫度(du):正常(chang)使(shi)用(yong)時(shi)的(de)環(huan)境溫(wen)度(du)為(wei)-40-+55C,特殊(shu)氣(qi)候條件時(shi)由廠(chang)家監制(zhi)單位與(yu)用戶共同協商(shang)定(ding)做(zuo)。
2、適用(yong)範圍:本產(chan)品有(you)分相(xiang)式和組(zu)合式大(da)類(lei),線(xian)卡分彈簧(huang)壓(ya)緊(jin)式和螺旋式兩大(da)類(lei)。其(qi)中(zhong)螺旋壓(ya)緊(jin)式的平(ping)口線(xian)卡適用於(yu)銅、鋁(lv)排(pai)母(mu)線和(he)室內(nei)開關(guan)櫃內停(ting)電(dian)檢修(xiu)之用,彈(dan)簧壓(ya)緊(jin)鱷(e)魚式(鍔(e)口線(xian)卡)適用於(yu)500千伏(fu)線(xian)路(lu)停(ting)電(dian)檢修(xiu)之用。其(qi)余線卡接口(kou)直(zhi)徑(jing)適(shi)應不(bu)同(tong)額定(ding)短路電(dian)流(liu)的導線(xian)接地(di)需要(yao),確保檢修(xiu)時(shi)的(de)人(ren)身(shen)安全。
三、使(shi)用(yong)方法:
1、分相(xiang)式:“接地(di)線(xian)”每(mei)套三組(zu),每(mei)組(zu)由導線(xian)端(duan)線卡、短路線(xian)和(he)接地(di)端(duan)線卡連接成(cheng)壹(yi)體(ti)。使(shi)用時(shi)分組(zu)進(jin)行(xing)操作(zuo)。按(an)規程規定(ding)先(xian)驗(yan)電(dian),確認(ren)已停(ting)電(dian)後,首(shou)先(xian)將接地(di)端(duan)線卡,緊固在接地(di)極(ji)上(shang),然(ran)後(hou)按(an)停(ting)電(dian)線路(lu)電(dian)壓(ya)等(deng)級(ji),選(xuan)定(ding)操(cao)作(zuo)棒,將導線(xian)端(duan)線卡掛(gua)在導線(xian)上(shang)。工作(zuo)完畢(bi),應先(xian)拆除(chu)導線(xian)端(duan)線卡,後拆除接地(di)端(duan)線卡。
2、組(zu)合式:“接地(di)線(xian)”由於(yu)電(dian)壓(ya)等(deng)級(ji)不(bu)同(tong),線(xian)卡組(zu)合形式及數量(liang)、導線(xian)長(chang)短也不(bu)相(xiang)同,壹般(ban)由三(san)只導線(xian)端(duan)線卡,短路線(xian)、接地(di)線(xian)及(ji)壹(yi)只接地(di)端(duan)線卡組(zu)成壹份“接地(di)線(xian)”。使(shi)用(yong)時(shi)按(an)規程規定(ding)先(xian)驗(yan)電(dian),確認(ren)已停(ting)電(dian)後,將接地(di)端(duan)線卡緊固在接地(di)極(ji)上(shang),然(ran)後(hou)按(an)不(bu)同(tong)電(dian)壓(ya)等(deng)級(ji)使(shi)用相(xiang)應的操作(zuo)棒將導線(xian)端(duan)線卡分別掛(gua)在導線(xian)上(shang)。(操作(zuo)棒有(you)固定(ding)式和折疊(die)式)拆除(chu)時(shi)應先(xian)拆除(chu)導線(xian)端(duan)線卡,後拆除地(di)線(xian)端(duan)線卡。
3、經(jing)受短路電(dian)流(liu)後,接地(di)線(xian)應做(zuo)報廢(fei)處理(li)。
四(si)、維(wei)護與(yu)保養(yang):
1、每(mei)組(zu)“接地(di)線(xian)”在使用(yong)過程中不(bu)得(de)扭(niu)花(hua),不(bu)用(yong)時(shi)應將軟(ruan)銅線(xian)盤好,存放在幹燥的室(shi)內(nei)。
2、接地(di)線(xian)在使用(yong)之前(qian)應檢查(zha):軟(ruan)銅線(xian)是(shi)否斷(duan)頭(tou),螺絲連接處有(you)無松(song)動(dong),軟(ruan)銅線(xian)有(you)無裸(luo)露(lu),不(bu)符合要(yao)求(qiu)不(bu)得(de)作(zuo)用,應修好後(hou)在使用(yong)。
3、接地(di)線(xian)不(bu)得(de)隨地(di)亂(luan)摔(shuai),註意清(qing)潔工作(zuo),預防(fang)泥沙(sha)、臟(zang)物進(jin)入(ru)接地(di)裝(zhuang)置(zhi)的(de)孔(kong)隙(xi)之中,從(cong)而(er)影(ying)響(xiang)正常(chang)使(shi)用(yong)的(de)零(ling)件及(ji)時(shi)更(geng)換(huan)。
4、接地(di)線(xian)在拆除(chu)後,不(bu)得(de)從空中(zhong)丟(diu)下(xia),確保下(xia)次能正常(chang)使(shi)用(yong)。
5、接地(di)線(xian)應定(ding)期(qi)進(jin)行(xing)檢修(xiu),影(ying)響(xiang)正常(chang)使(shi)用(yong)的(de)零(ling)價及時(shi)更(geng)換(huan)。